Dietz 170D

DIETZ MODELS 170D AND 171D SPECIFICATIONS

Adobe AcrobatDietz 170D / 171D Technical Specifications (526KB PDF)


Operating Ranges
  • A variety of models, with factory-set actuation points from 0.05" to 40.0" H2O (171D)
  • Actuation points can be adjusted within the limits on switch nameplate
Electrical
  • Single pole double throw snap-switch
Construction
  • 0.008" Buna (Nitrile) coated nylon diaphragm for temps of -30° F to 160° F. Silicone coated cloth can be used for greater temperature extremes
  • Sturdy zinc die cast, steel, and aluminum stampings
  • For military use, aluminum parts can be anodized in accordance with Military Specification MIL-A-8625, Class 2, Type I. Snap switch bodies are of a non-nutrient plastic material.

DIETZ MODELS 170D / 171D

Ultra Low Differential Pressure Switches for Harsh Environments

The Dietz Model 170D Ultra Low Differential Pressure Switch combines extremely low pressure actuation, maximum electrical ratings and rugged construction to withstand unusually harsh environments. The 171D is shock and vibration resistant, due to a minimum number of moving parts and the absence of lever amplifiers, and will actuate at 1" H2O under extreme shock and vibration conditions. Overpressure of 25 lbs. per square inch will not damage the switch or change calibration settings. Diaphragm movement is limited to provide extremely long diaphragm life.

This rugged but simple design makes the Dietz 170D ideal for use on locomotives, ships, construction equipment, and variety of outdoor applications. A highly resistant epoxy finish is available for use where corrosive fumes or acids are present, such as in chemical plants, plating rooms, and sewage plants.

FEATURES / BENEFITS

  • Sense pressure, vacuum, or differential pressure
  • Shock and vibration resistant (MIL-STD-167-1 and MIL-STD-901-D)
  • Covers a broad operating range
  • Model 171D actuates at 0.05" H2O
  • Heavy gauge steel mounting bracket
  • Gasket seals cover against dirt and oil
  • Pressure connection available for use with liquids

APPLICATIONS

  • Air flow interlock
  • Liquid level control
  • Output for fluid amplifiers
  • Measurement, sensing, switching, sequencing in simple fluidic circuits requiring an auxiliary air supply

AC Switches

Operating Range

Approximate Dead Band

125V, 250V, 480V
60 Cycle AC
1/8 HP 125V AC
1/4 HP 250V AC

   

Min.

Max.

 

170D8W-S

1.0" to 8.0" H20

0.2" H2O

0.4" H2O

10 Amp VAC

170D8W

2.0" to 8.0" H20

0.3" H2O

0.5" H2O

15 Amp VAC

170D20W

2.0" to 20.0" H20

0.3" H2O

0.5" H2O

15 Amp VAC

170D40W

2.0" to 40.0" H20

0.3" H2O

0.5" H2O

15 Amp VAC


DC Switches

Operating Range

Approximate Dead Band

75 DC 0.5A
Inductive Load 0.75A
Restrictive Load
0.5A-125V DC
0.25A-250V DC

   

Min.

Max.

 

170D8W-S-DC

1.0" to 8.0" H20

0.4" H2O

0.6" H2O

10 Amp VAC, VDC - see above

170D8W-DC

2.0" to 8.0" H20

0.8" H2O

1.0" H2O

15 Amp VAC, VDC - see above

170D20W-DC

2.0" to 20.0" H20

0.8" H2O

1.0" H2O

15 Amp VAC, VDC - see above

170D40W-DC

2.0" to 40.0" H20

0.8" H2O

1.0" H2O

15 Amp VAC, VDC - see above

171D8WC-S

0.05" to 8.0" H2O

0.03" H2O

0.3" H2O

10 Amp VAC, VDC - see above

171D8WC

0.15" to 8.0" H2O

0.05" H2O

0.3" H2O

15 Amp VAC, VDC - see above

171D8WC-S-DC

0.05" to 8.0" H2O

0.03" H2O

0.3" H2O

0.75 Amp VAC, 75 VDC - see above